UPS UPS
BASIC 1K

SPECIFIKACIJA
TECHNOLOGY:
True On-Line, Double Conversion
CLASSIFICATION:
VFI-SS-111 (EN 62040-3)
POWER RANGE:
1 kVA
No. OF PHASES:
1:1

APPLICATION:

Servers, Work stations, Industrial facilities and equipment, Laboratory apparatus, Telecommunication, Automation and control systems

DOWNLOAD:

KARAKTERISTIČNA
  • Technology True On-Line Double Conversion provides excellent output voltage parameters regardless of power disturbances and the type of receivers being powered.
  • Rectifier IGBT the most advanced technology ensuring very low THDi and high power factor.
  • Automatic bypass - uninterrupted ensures uninterrupted power supply to critical loads such as overheating or failure.
  • Communication interfaces:
    - RS232, USB to monitor and manage the operation of the power supply and receivers,
    - SNMP integration with NMS network management systems ,
    - Remote switch connector against Fire (REPO) to ensure remote disconnection of power supply to receivers in the event of a fire,
    - Switch aginst Fire (EPO) on the control panel it enables immediate disconnection of power from the receivers,
  • LCD panel clearly informs about the operating mode, parameters of the UPS and enables configuration of the UPS parameters.events.
  • Small dimensions , so minimal space is required to install the device.
  • High efficiency of the device 90% minimizes energy consumption and limits the heat emitted, which makes possible cooling of rooms cheaper.
  • ECO-Mode (HE) It allows for a significant reduction of the unit's operating costs and virtually eliminates heat emission.
  • CVCF frequency converter mode allows the power supply to operate in the output frequency
  • Automatic diagnostics fully digital control (32 bit DSP x2) guarantees full device efficiency, control of components and operating parameters without the need for user intervention.
  • High value of the input power factor limits the value of the current consumed by the device from the network.
  • High value of the output power factor guarantees even more active power compared to other power supplies of this class
  • A wide range of input frequencies in the normal operation mode, it allows free use of the power supply in a network with unstable parameters and power supply from the generator set.
  • TOWER compact housing makes the UPS take up little space and is suitable for installation both under the desk and in places with limited space.
  • Autorestart guarantees unattended operation of the device in the event of long power outages.
  • Excellent quality of output voltage achieved thanks to the use of high-frequency PWM modulation, ensures that voltage with extremely stable parameters is supplied, regardless of energy interference and the type of powered devices.
  • High overload it is supply reliability in the presence of transients and high tolerance to operating errors.
  • Advanced software allowing the user full control over the device and powered receivers.
  • Battery start (so-called cold start) gives the possibility to start the power supply even in the event of a complete lack of power supply.
PARAMETRI
Model Basic 1K
Power 1kVA / 0,9kW
No of phases IN : OUT 1:1
Input
Nominal voltage 208 / 220 / 230 / 240 Vac
Voltage range 110 ÷ 300 Vac
Frequency 50/60 Hz
Frequency range 47 ÷ 63 Hz
THDi <3%
Input power factor ≥0,99
Output
Nominal voltage 208 / 220 / 230 / 240 Vac
Power factor 0,9
Static / dynamic voltage regulation ±1% / ±3%
Nominal frequency 50 / 60 ± 0,05 Hz
Inverter overload resistance 110% - 10 min., 130% - 60 s., >130% - 3s.
Efficiency in On-Line mode >90%
Efficiency in Eco mode 99%
Crest factor 3:1
No. of outlets 3*IEC320 C13
Battery
Cold start Yes
Internal batteries 2 pcs
Charging time 3 - 8 hours to 90% capacity (configurable)
Charging cycle According to DIN 41773 with automatic shutdown of charging according to the criterion of current and voltage, with time control.
Dimensions and weight

Dimensions and weight UPS (W x D x H)

145 x 282 x 220 mm
9,8 kg
Signaling and communication ports
Work status indicator LCD + audible alarm
Standard communication RS232, USB, SNMP slot, EPO - option
Environmental conditions
Noise level <49 dB
Permissible operating temperature 0°C ÷ 45°C
Recommended working temperature 15 °C ÷ 25 °C
Storage temperature -25°C ÷ 55°C
Humidity 0 ÷ 95% (without condensation)
Standards
Resistance to interference EN 62040-2:2005, EN 62040-2:2006
Safety IEC62040-1-1, CE, 62040-3 :2001
Optional equipment
- SNMP card
- RS485 (MODBUS) card,
- AS400 mini (dry-contact) card,
- Environment monitor device,
- Automatic transfer switch (ATS),
- EPO


In the publication are given standard parameters of our models. Due to continuous product improvement, we reserve the right to change parameters without prior notice.
VI - Line Interactive (VI in accordance with PN-EN 62040-3)
VFI - True On Line (VFI in accordance with PN-EN 62040-3)

SELECT ANOTHER UPS

BW
Model
BW300
Tip
VFI-SS-111
Domet
30 - 300 kVA
Tip
3:3
CORE
Model
CORE 1-3
Tip
UPS VFI
Domet
1-3 kVA
Tip
1:1
CORE 3K TL
Model
CORE 3K TL
Tip
UPS VFI
Domet
3 kVA
Tip
1:1
CORE
Model
CORE 6-10
Tip
UPS VFI
Domet
6-10 kVA
Tip
1:1
HS105
Model
HS105
Tip
UPS VFI
Domet
50 - 100 kVA
Tip
3:3
HS205
Model
HS205
Tip
UPS VFI
Domet
50 - 200 kVA
Tip
3:3
HS305
Model
HS305
Tip
UPS VFI
Domet
50 - 300 kVA
Tip
3:3
HS505
Model
HS505
Tip
UPS VFI
Domet
50 - 500 kVA
Tip
3:3
UPS JR
Model
JR
Tip
UPS VFI
Domet
10 - 20 kVA
Tip
3:3 / 3:1
MR
Model
MR
Tip
VFI-SS-111
Domet
50 ÷ 600 kVA
Tip
3:3
MY 30K
Model
MY 30K
Tip
UPS VFI
Domet
30 kVA
Tip
3:3 / 3:1
MZ 60K-200K
Model
MZ 60K-200K
Tip
UPS VFI
Domet
60 - 200 kVA
Tip
3:3
NGS 40
Model
NGS 40
Tip
UPS VFI
Domet
40 kVA
Tip
3:3
PKX
Model
PKX
Tip
UPS VFI
Domet
10 kVA
Tip
3:3
PRM 6
Model
PRM 6
Tip
UPS VFI
Domet
6 kVA
Tip
1:1
UPS  WINTER
Model
WINTER
Tip
UPS VI
Domet
3 kVA
Tip
1:1

SHORTCUTS

Pracownik w kasku ochronnym Do you need help?
Tel: +48 58 556 13 13
E-mail: info@comex.com.pl

comex Filing a Complaint