UPS UPS
MY 30K

SPECIFICATION
TECHNOLOGY:
True On-Line, Double Conversion
CLASSIFICATION:
VFI-SS-111 (EN 62040-3)
POWER RANGE:
30 kVA
No. OF PHASES:
3:3 / 3:1

APPLICATION:

Large computer networks, Data processing centers, Industrial facilities and equipment, Laboratory equipment, Telecommunication, Automation and control systems

DOWNLOAD:

CHARACTERISTICS
  • Technology True On-Line Double Conversion provides excellent output voltage parameters regardless of power disturbances and the type of receivers being powered.
  • Rectifier IGBT the most advanced technology ensuring very low THDi and high power factor.
  • Automatic bypass - uninterrupted ensures uninterrupted power supply to critical loads such as overheating or failure.
  • Service bypass - enables servicing of devices without switching off powered receivers. Separate power supply Bypass track provides the ability to provide a reserve power source for receivers even in the event of a device failure or UPS protection in the main track.
  • Communication interfaces:
    - RS 232, RS 485, ModBus to monitor and manage the operation of the power supply and receivers,
    - DryContact in/out relay contacts for cooperation with BMS systems,
    - SNMP integration with NMS network management systems ,
    - Remote switch connector against Fire (REPO) to ensure remote disconnection of power supply to receivers in the event of a fire,
    - Switch aginst Fire (EPO) on the control panel it enables immediate disconnection of power from the receivers,
  • Touch control and monitoring panel gives the possibility of diagnostics of parameters and operation mode of the power supply and enables registration of events. Available languages include Polish, English.
  • Small dimensions, thanks to which a large space for installing the device is not required.
  • High efficiency of the device 96% It reduces the own losses of the device and reduces the heat emitted, making possible cooling of the rooms easier and cheaper.
  • ECO-Mode (HE) It allows for a significant reduction of the unit's operating costs and virtually eliminates heat emission.
  • Configured amount of batteries and charging current it enables precise selection of the required time of autonomy.
  • Configuration of the output 3:3 or 3:1 allows you to adjust the number of outputs depending on the receiving system and the way of powering your receivers.
  • Function Self-Aging allows you to test the device with full load, even without connected receivers.
  • Automatic diagnostics with FTM (Fault Trace Management) and fully digital control (32 bit DSP x2) guarantees full device efficiency, control of components and operating parameters without the need for user intervention.
  • High value of the input power factor limits the value of the current consumed by the device from the network.
  • Maximum value of the output power factor PF = 1 provides 20% more active power than standard solutions with PF = 0.8.
  • Maximum wide input voltage range -60% ÷ + 25% in normal operation mode, it ensures stable operation of the device without the need to use batteries, which significantly affects the extension of their service life.
  • A wide range of input frequencies in the normal operation mode, it allows free use of the power supply in a network with unstable parameters and power supply from the generator set.
  • Simplicity of use ease of connection to the network and simple switching on and off of the device does not require special qualifications from the user.
  • Advanced battery management it guarantees optimal charging and use of batteries, increases their lifespan and lowers operating costs.
  • Excellent quality of output voltage achieved thanks to the use of the IGBT inverter using highly advanced PWM control technology, it provides voltage with stable parameters, regardless of the power disturbances and the type of powered equipment.
  • High overload provides device protection and continuity of power supply in the presence of transient transients, and reduces the need for oversizing the device in relation to the power of the receivers.
  • Advanced software allowing the user full control over the device and powered receivers.
  • Configurable work parameters nominal voltages, frequencies, preferred modes of operation, communication method - significantly broadens the range of possible applications.
  • Redundant configurations:
    - Redundant work for increased reliability
    - Capacitive parallel operation for increased power
    - HotStandby operation (separated rectifier and bypass power supply)
PARAMETERS
Model MY 30K
Power 30 kVA / 30 kW
No of phases IN : OUT 3:3 / 3:1
Input
Nominal Voltage 220 / 230 / 240 VAC or 380 / 400 / 415 VAC (configurable)
Voltage range -25% ÷ + 25% @ 100% load
-65% ÷ + 25% @ linear limited load
Frequency 50/60 Hz
Frequency range -20% ÷ +20%
THDi <3%
Input power factor ≥0,99
Output
Nominal voltage 220 / 230 / 240 VAC or 380 / 400 / 415 VAC (configurable)
Power factor 1,0
Static / dynamic voltage regulation ±1% / ±3%
THDu linear / not linear load <1% / <3%
Nominal frequency 50/60 Hz ±0,1 Hz
Inverter overload resistance 105% - cont.; 115% - 60 min., 130% - 10 min., 150% - 60 sec., >155% - 0,2 sek.
Efficiency in On-Line mode 96%
Efficiency in Eco mode 99%
Crest factor 3:1
Battery
Type Sealed maintenance-free VRLA
Max. amount of internal batteries 2 x 40 x 7/9 Ah
No. of batteries in string Configurable: 24 ÷ 40 psc
(for a string with a length of 24-30 pieces power limitation to 75% of the nominal value)
Maximum charging current 1 ÷20 A
Charging time 3 - 8 hours to 90% capacity (configurable)
Charging cycle According to DIN 41773 with automatic shutdown of charging according to the criterion of current and voltage, with time control.
Bypass
Automatic bypass Static switch type Bypass, uninterruptible changeover
Bypass manual mechanical Standard
Dimensions and weight

Dimensions and weight of UPS (W x D x H)

300 x 834 x 1250 mm
85 kg
Signaling and communication ports
Work status indicator 4.3" touch display, LED indicators, audible alarm
Standard communication 3 x Smart Slot for additional communication cards,
REPO (NC), 5 x Dry Contact Out, 1 x Dry Contact In, RS485, Modbus.
RS232, SNMP: option.
Environmental conditions
Noise level <50 dB
Permissible operating temperature 0°C ÷ 40°C
Recommended working temperature 15°C ÷ 25°C
Storage temperature -25°C ÷ 55°C
Humidity 0 ÷ 95% (without condensation)
Standards
Resistance to interference EN 62040-2:2005, EN 62040-2:2006
Safety IEC62040-1-1, CE, EAC
Optional equipment
- SNMP card,
- Uninterruptible Bypass External
- Additional Dry Contact card
- Batteries in rack or in battery modules
- Sensor for battery voltage compensation
- Remote signaling panel

In the publication are given standard parameters of our models. Due to continuous product improvement, we reserve the right to change parameters without prior notice.
VI - Line Interactive (VI in accordance with PN-EN 62040-3)
VFI - True On Line (VFI in accordance with PN-EN 62040-3)

SELECT ANOTHER UPS

BASIC 1K
Model
BASIC 1K
Type
UPS VFI
Range
1 kVA
Class
1:1
CORE
Model
CORE 1K
Type
UPS VFI
Range
1 kVA
Class
1:1
CORE 3TL
Model
CORE 3TL
Type
UPS VFI
Range
3 kVA
Class
1:1
CORE
Model
CORE 6-10K
Type
UPS VFI
Range
6-10 kVA
Class
1:1
CORE ONE 2-3K
Model
CORE ONE 2-3K
Type
UPS VFI
Range
2-3 kVA
Class
1:1
FRAME
Model
FRAME 60-200K
Type
VFI-SS-111
Range
60-200 kVA
Class
3:3
HS305
Model
HS305
Type
UPS VFI
Range
50 - 300 kVA
Class
3:3
HS505
Model
HS505
Type
UPS VFI
Range
50 - 500 kVA
Class
3:3
JR 10-20K
Model
JR 10-20K
Type
UPS VFI
Range
10 - 20 kVA
Class
3:3 / 3:1
MR
Model
MR
Type
VFI-SS-111
Range
50 ÷ 600 kVA
Class
3:3
MZ 60K-200K
Model
MZ 60K-200K
Type
UPS VFI
Range
60 - 200 kVA
Class
3:3
NGS 40K
Model
NGS 40K
Type
UPS VFI
Range
40 kVA
Class
3:3
PKX
Model
PKX 10K
Type
UPS VFI
Range
10 - 100 kVA
Class
3:3
WINTER 3K
Model
WINTER 3K
Type
UPS VI
Range
3 kVA
Class
1:1

SHORTCUTS

Pracownik w kasku ochronnym Do you need help?
Tel: +48 58 556 13 13
E-mail: info@comex.com.pl

comex Filing a Complaint