UPS UPS
JR 10-20K

SPECIFICATION
TECHNOLOGY:
TRUE ON LINE Double Conversion
CLASSIFICATION CODE:
VFI - SS - 111
POWER RANGE:
10 - 20 kVA
PHASE CONFIGURATION:
3:3 / 3:1
SOFTWARE:
ViewPower

APPLICATIONS:

Computer networks, Data processing centers, Industrial equipment, Clusters, Tele information systems, Automation and control systems

DOWNLOAD:

CHARACTERISTICS
  • Technology True On-Line Double Conversion Technology provides perfect output voltage parameters, regardless of the input voltage and the load.
  • Rectifier IGBT the most advanced technology which provides very load THDi and high power factor.
  • Automatic bypass provides continuous load supply in critical conditions, such as overheating or inverter failure.
  • Maintenance bypass enables service handling without necessity of shutting off the load.
  • Communication:
    - USB, Intelligent slot to monitor and manage the operation of the power supply and receivers,
    - DryContact alarm indicators; work with BMS system
    - SNMP integration with systems management network NMS.
  • Remote emergency power off (REPO) provides remote shutting off the load and UPS in the case of emergency.
  • Emergency power off (EPO) on UPS provides very quickly shutting off the load and UPS.
  • LCD control panel displays UPS and power parameters as well as hundreds of useful information.
  • Small dimensions requires small area for unit operation.
  • High efficiency (>96%) reduces heat dissipation and limits power consumption costs.
  • ECO-Mode gives possibility of significant cost reduction and in practice stops heat emission.
  • Automatic diagnostics and fully digital control (2x 32bit DSP) ensure that components and parameters are controlled without user interference.
  • High input power factor 0,99 reduces the value of current drawn from the mains.
  • The highest output power factor up to 1,0 allows load of versatile characteristics to be powered.
  • Wide input voltage range for normal mode ensures that batteries are used only if necessary – in fact, only when the input voltage is completely lost.
  • Wide input frequency range for normal mode gives possibility for seamless operation with different power sources – as mains or the generating set.
  • Simple maintenance microprocessor control and 24/7 operation mode means that unit does not require specialized handling.
  • Advanced battery management gives reliability of optimal charging and using batteries, elongates its lifetime and reduces operating costs.
  • Excellent voltage quality is provided by 3level IGBT inverter ad high frequency PWM technology, the output voltage has always stable parameters independent of input disturbances and the load characteristics.
  • Advanced software provides to customer full control of unit and load.
  • User configurable settings enable user to set nominal voltages, frequency, preferred operating modes.
  • Redundancy configurations:
    - Parallel for capacity or redundancy
    - Hot Standby
PARAMETERS
Model JR 10K JR 15K JR 20K
Power 10 kVA / 10 kW 15 kVA  / 15 kW 20 kVA  / 20 kW
No. Of phases IN : OUT 3:3 / 3:1 
Input
Voltage 380 / 400 / 415 VAC
Voltage range -53% ÷ +30%
Frequency 50 / 60 Hz
Frequency range -20% ÷ +20%
THDi <3%
Input power factor ≥0,99
Output
Voltage 380 / 400 / 415 VAC or 220 / 230 / 240 VAC
Power factor 1,0
Voltage regulation static/dynamic ±1% / ±2%
THDu linear / not linear load <1% / <3%
Frequency 50 / 60 ± 0,05 Hz
Overload capacity inverter 110% - 60 min., 125% - 10 min., 150% - 60 s, >150% - 300 ms
Overload capacity bypass 125% - continuous, 130% - 10 min., 150% - 1 min., >150% - 300 ms
Shot-circuit resistance 340% value of nominal current for 200 ms
Efficiency in On-Line mode/Eco mode >96% / 99%
Crest factor 3:1
Batteries
Cold start Yes
Amount of batteries in string 16 - 20 pcs x 12 V or 32 - 40 psc x 12V 32 – 40 psc x 12 V
Max amount of internal batteries 40 pcs of 7/9 Ah
Max charger current 12A
Charging time 3 – 8 hours up to 90% of capacity (configurable)
Weight and dimensions
Dimensions (W x D x H) 250 x 627 x 827 mm
Weight 44 kg 47 kg
Communications
Working indicator LCD + indicators LED, sound alarm
Communication USB , IntelligentSlot, EPO, parallel work, RS232
Options: SNMP, DryContact, Modbus, RS485
Environmental
Noise level <58 dB @ load. 100%, <52 dB @ load. 50%
Operating temperature 0°C ÷ 40°C
Recommended operating temperature 15°C ÷ 25°C
Storage temperature -20°C ÷ 40°C
Humidity 0 ÷ 95% (without condensing)
Standards
Standards EN 62040-2:2005, EN 62040-2:2006
Safety IEC62040-1-1, CE, 62040-3 :2001
Options
- Uninterruptible external maintenance bypass
- SNMP card
- Environment Sensor
- ModBus card
- Battery Cold Start
- Parallel card
- DryContact card

In the publication are given standard parameters of our models. Due to continuous product improvement, we reserve the right to change parameters without prior notice.
VI - Line Interactive (VI in accordance with PN-EN 62040-3)
VFI - True On Line (VFI in accordance with PN-EN 62040-3)

SELECT ANOTHER UPS

BASIC 1K
Model
BASIC 1K
Type
UPS VFI
Range
1 kVA
Class
1:1
CORE
Model
CORE 1K
Type
UPS VFI
Range
1 kVA
Class
1:1
CORE 3TL
Model
CORE 3TL
Type
UPS VFI
Range
3 kVA
Class
1:1
CORE
Model
CORE 6-10K
Type
UPS VFI
Range
6-10 kVA
Class
1:1
CORE ONE 2-3K
Model
CORE ONE 2-3K
Type
UPS VFI
Range
2-3 kVA
Class
1:1
FRAME
Model
FRAME 60-200K
Type
VFI-SS-111
Range
60-200 kVA
Class
3:3
HS305
Model
HS305
Type
UPS VFI
Range
50 - 300 kVA
Class
3:3
HS505
Model
HS505
Type
UPS VFI
Range
50 - 500 kVA
Class
3:3
MR
Model
MR
Type
VFI-SS-111
Range
50 ÷ 600 kVA
Class
3:3
MY 30K
Model
MY 30K
Type
UPS VFI
Range
30 kVA
Class
3:3 / 3:1
MZ 60K-200K
Model
MZ 60K-200K
Type
UPS VFI
Range
60 - 200 kVA
Class
3:3
NGS 40K
Model
NGS 40K
Type
UPS VFI
Range
40 kVA
Class
3:3
PKX
Model
PKX 10K
Type
UPS VFI
Range
10 - 100 kVA
Class
3:3
PS
Model
PS 10-40K
Type
VFI-SS-111
Range
10 - 40 kVA
Class
1:1, 3:1, 3:3,1:3
WINTER 3K
Model
WINTER 3K
Type
UPS VI
Range
3 kVA
Class
1:1

SHORTCUTS

Pracownik w kasku ochronnym Do you need help?
Tel: +48 58 556 13 13
E-mail: info@comex.com.pl

comex Filing a Complaint
Tel: +48 58 556 13 13
E-mail: info@comex.com.pl