UPS UPS
INSERT 15-40K

SPECIFIKACIJA
TECHNOLOGY:
TRUE ON LINE Double Conversion
CLASSIFICATION:
VFI-SS-111 (EN 62040-3)
POWER RANGE:
15, 20, 30, 40 kVA
No. OF PHASES:
3:3

 

APPLICATIONS:

Computers network, Data processing centers, Industrial equipment, Clusters, Tele information systems, Automation and control systems

DOWNLOAD:

KARAKTERISTIČNA
  • True On-Line Double Conversion technology provides excellent output voltage performance regardless of power interference and type of powered loads.
  • IGBT rectifier the most advanced technology providing very low THDi and a high input power factor of 0.99
  • Automatic bypass uninterruptible power supply provides uninterrupted power to consumers in critical situations such as overheating or failure.
  • Service bypass allows servicing of equipment without shutting down the powered.
  • Communication:
    USB, RS232, RS485 for reading and monitoring parameters, management operation and configuration of the UPS
    DryContact relay contacts for interfacing with BMS systems
    SNMP integration with systems management network NMS.SNMP integration with NMS-type network management systems
  • Emergency power off Connector (EPO) for providing remote disconnection of power supply to consumers in case of fire
  • The 5.0" LCD color touchscreen control and monitoring panel makes it easy to UPS operation, allows diagnostics of parameters and power supply operation mode and allows event logging.
  • The highly efficient charging system gives the UPS the ability to quickly charge battery banks with very large capacities, for achieving long autonomous operation times.
  • The unit's high efficiency (>96%) limits the heat emitted, making it making the eventual cooling of rooms simpler, and the operation of the UPS is much cheaper.
  • ECO-Mode allows a significant reduction in the cost of operation of the device and virtually eliminates heat emission thanks to >99% efficiency.
  • Internal batteries up to 160pcs x 9Ah ensure the unit's small size with using basic battery packs. The batteries do not require additional space for installation.
  • Adjustable battery quantity allows you to fine tune the amount of batteries for the required backup time.
  • Conformal coating protecting the UPS boards insulates the electronic components electronics from adverse environmental conditions like moisture, dust, dust and surges.
  • Automatic diagnostics and digital control (32 bit DSP x2) guarantees full device performance, component control and operating parameters without user intervention.
  • Redundant fans ensure UPS operation even in case of failure of 1 or 2 fans, with limited output power.
  • Highest output power factor of 1.0 allows for load the power supply with full active power.
  • The wide input voltage range in normal operation ensures stable operation of the device without the need to use batteries, which significantly contributes to extending their service life.
  • The wide input frequency range in normal operation mode allows the power supply to be freely used in a network with unstable parameters and with power supply from a generator set.
  • Advanced battery management guarantees optimal charging and utilization of the battery bank, increases battery life and reduces operating costs. Temperature compensation function charging voltage.
  • The excellent quality of the output voltage, achieved through the use of a 3-level IGBT inverter, with the use of advanced PWM control technology, makes it possible to deliver a voltage with stable parameters, regardless of energy disturbances and the type of powered devices.High overload capacity provides protection of the device and continuity of power supply when transient transients occur.
  • Advanced software that allows the user to fully control over the device and powered loads.
  • Configurability of operating parameters nominal voltages, frequencies, preferred modes of operation, method of communication - greatly expands the range of of possible applications.
  • Redundant configurations:
    - redundant parallel operation for increased reliability
    - capacitive parallel operation for increased power
    - HotStandby operation
PARAMETRI
Model INSERT 15K INSERT 20K INSERT 30K INSERT 40K
Power [kVA]/kW] 15 / 15 20 / 20 30 / 30 40 / 40
Number of phases IN : OUT 3:3
Input
Supply voltage 380 / 400 / 415 VAC
Voltage range 304 VAC - 485 VAC for 100% load
Min. 138 VAC - 304 VAC linear for 40% - 100% load
Frequency 50 / 60 Hz
Frequency 40 - 70 Hz
THDi <3%
Input power factor ≥0,99
Output
Nominal voltage 380 / 400 / 415 VAC
Power factor 1,0
Static/dynamic voltage regulation ±1% / ±2%
Nominal frequency 50 / 60 ± 0,05 Hz
Inverter overload 105% - 110% - 60 min., 110% - 125% - 10 min., 125% - 150% - 1 min., >150% - 0.2 sec.
Efficiency in On-line mode >96%
Efficency in Eco Mode 99%
Creast factor 3:1
Battery
Cold start Yes
Battery type VRLA, AGM, GEL
Number of batteries in 1 string 32 - 40 szt. x 12V
Number of internal batteries Max. 3x40 pcs Max. 2x40 pcs Max. 4x40 pcs
Max capacity of charging system 10 A 15 A
Charging time 3 - 8 hours up to 90% capacity (configurable)
Charging cycle In accordance with DIN 41773 with automatic charge deactivation according to current and voltage criteria, with time control, temperature-compensated charging voltage option
Dimensions and weight
Wymiary S x G x W [mm] 350 x 770 x 1085 450 x 950 x 1178 600 x 950 x 1178
Masa UPS bez baterii 91,8 kg 158,6 kg 192,7 kg
Number of internal batteries 40/80 pcs 40/80/120 pcs 40/80/120/160 pcs
Masa UPS z bateriami 7 Ah 179,8 kg/267,8 kg 246,6 kg/334,6 kg/422,6 kg 280,7 kg/368,7 kg/456,7 kg/544,7 kg
Masa UPS z bateriami 9 Ah 199,8 kg/307,8 kg 266,6 kg/374,6 kg/482,6 kg 300,7 kg/408,7 kg/516,7 kg/624,7 kg
Signalling and communication ports
Operating status indicator 5-inch touchscreen LCD, LED diode, audible alarm
Communication USB, RS232, RS485, EPO, Parallel operation connector, DryContact x6
Optional: SNMP card, Battery temperature sensor
Environmental conditions
Noise level <58 dB @ 100% load / <55 dB @ 50% load
Permissible operating temperature 0°C ÷ 40°C
Recommended operating temperature 15°C ÷ 25°C
Storage temperature -25°C ÷ 55°C
Humidity 0 ÷ 95% (non-condensing)
Standards
Resistance to interference EN62040-2:2018
Safety EN62040-1:2019, EN62040-3:2011, CE
Optional equipment
- SNMP card
- Environmental conditions sensor
- Temperature sensor for battery charging voltage compensation
- Uninterruptible External Bypass, Service
- BackFeed Protection
- Battery rack or battery modules

The publication gives the parameters of the standard models. Due to continuous product improvement, the parameters are subject to change without prior notice.
VI - Line Interactive (VI in accordance with PN-EN 62040-3)
VFI - True On Line (VFI in accordance with PN-EN 62040-3)

SELECT ANOTHER UPS

BASIC 1K
Model
BASIC 1K
Tip
UPS VFI
Domet
1 kVA
Tip
1:1
CORE
Model
CORE 6-10
Tip
UPS VFI
Domet
6-10 kVA
Tip
1:1
CORE ONE 1-3K
Model
CORE ONE 1-3K
Tip
UPS VFI
Domet
1-3 kVA
Tip
1:1
FLIX 6K
Model
FLIX 6K
Tip
UPS VI
Domet
6 kVA
Tip
1:1
FRAME
Model
FRAME 60-200K
Tip
VFI-SS-111
Domet
60-200 kVA
Tip
3:3
HS305
Model
HS305
Tip
UPS VFI
Domet
50 - 300 kVA
Tip
3:3
HS505
Model
HS505
Tip
UPS VFI
Domet
50 - 500 kVA
Tip
3:3
JR 10-20K
Model
JR 10-20K
Tip
UPS VFI
Domet
10 - 20 kVA
Tip
3:3 / 3:1
MY 30K
Model
MY 30K
Tip
UPS VFI
Domet
30 kVA
Tip
3:3 / 3:1
PS
Model
PS 10-40K
Tip
VFI-SS-111
Domet
10 - 40 kVA
Tip
1:1, 3:1, 3:3,1:3
UPS  WINTER
Model
WINTER
Tip
UPS VI
Domet
3 kVA
Tip
1:1

SHORTCUTS

Pracownik w kasku ochronnym Do you need help?
Tel: +48 58 556 13 13
E-mail: info@comex.com.pl

comex Filing a Complaint
Tel: +48 58 556 13 13
E-mail: info@comex.com.pl