UPS UPS
NHS 120

SPECIFICATION
TECHNOLOGY:
True On-Line, Double Conversion
CLASSIFICATION CODE:
VFI - SS - 111
POWER RANGE:
30 - 120 kVA
PHASE CONFIGURATION:
3:3
SOFTWARE:
W opcji

APPLICATIONS:

Large computer networks, Data Processing Centres, facilities and equipment, laboratory equipment, telecommunication, automation and control systems

DOWNLOAD:

CHARACTERISTICS
  • The True On-Line Double Conversion technology ensures excellent output voltage parameters regardless of the power disturbances and the type of receivers being powered.
  • The modular structure provides the possibility of easy expansion of power and replacement of the "hot" power modules in the HotSwap technology. Scalability of power with a step of 30kVA / 30kW in the range of 30 - 120kVA.
  • 3-level IGBT rectifier - the most advanced technology ensuring very low THDi and high power factor as well as processing efficiency.
  • Automatic bypass - uninterruptible ensures uninterrupted power supply to critical loads such as overheating or failure.
  • Service bypass - allows servicing of devices without switching off powered receivers. Separate power supply Bypass track provides the ability to provide a reserve power source for receivers even in the event of a device failure or UPS protection in the main track.
  • Communication interfaces: RS232, RS485, MODBUS for monitoring and managing the operation of the power supply and receivers,
  • DryContact relay contacts for cooperation with BMS systems
  • SNMP integration with NMS network management systems,
  • Remote switch connector A. Fire (REPO) to ensure remote disconnection of power supply to receivers in the event of a fire,
  • A.Fire. Switch (EPO) on the control panel enables immediate disconnection of power from the receivers,
  • Control and monitoring panel LCD (touch) gives the opportunity to diagnose parameters and operation mode of the power supply, enables the registration of events and, among others, graphical preview of current and voltage waveforms.
  • Small dimensions, thanks to which a large space for installing the device is not required.
  • The high efficiency of the device (> 96%) reduces energy consumption and limits the heat emitted, making possible cooling of rooms easier and cheaper.
  • The ECO-Mode mode allows a significant reduction of the unit's operating costs and virtually eliminates heat emission.
  • Automatic diagnostics and fully digital control (32 bit DSP x2) guarantee full device efficiency, control of components and operating parameters without the need for user intervention.
  • The high value of the input power factor 0.99 limits the value of the current consumed by the device from the network.
  • The high value of the output power factor of 1.0 allows for supplying a wide range of receivers.
  • The wide range of input voltage in the normal operation mode ensures stable operation of the device without the need to use the battery, which significantly affects the extension of their service life.
  • A wide range of input frequencies in the normal operation mode allows free use of the power supply in a network with unstable parameters and when powered from a power generator.
  • Simple to use - easy to connect to the network and simple switching on and off the device does not require special qualifications from the user.
  • Advanced battery management ensures optimal charging and use of battery, increases their lifespan and lowers operating costs. Temperature compensation function of the charging voltage.
  • Excellent quality of the output voltage, achieved thanks to the use of a 3-level IGBT inverter using highly advanced PWM control technology, ensures that voltage is supplied with stable parameters, regardless of the power disturbances and the type of powered equipment.
  • High overload protection ensures device protection and continuity of power supply in the presence of transient transients.
  • Advanced software that allows the user full control over the device and powered receivers.
  • Configurable work parameters - nominal voltages, frequencies, preferred modes of operation, communication method - significantly broadens the range of possible applications.
  • Redundant configurations:
    - redundant work for increased reliability
    - capacitive parallel operation for increased power
    - HotStandby work
    - double-track work
PARAMETERS
Model NHS
Power 30kW / 30kVA - 120kW / 120kVA
No. of phases IN:OUT 3:3
Input
Nominal voltage 380 / 400 / 415 VAC
Voltage range -40% ÷ +25%
Frequency 50/60 Hz
Frequency range -20% ÷ +20%
THDi <2,5%
Input power factor ≥ 0,99
Output
Nominal voltage 380 / 400 / 415 VAC
Power factor 1,0
Static / dynamic voltage regulation ±0,5% / ±2%
Nominal frequency 50/60 ± 0,01 %
Inverter overload resistance 110% - 60 min., 125% - 10 min., 150% - 60 sek., >150% - 200msek.
Short-circuit resistance 340% of the nominal current for 200 ms
Efficiency in On-Line mode >96%
Eco Mode efficiency 99%
Creast factor 3:1
Batteries
Type Sealed, maintenance-free AGM type VRLA
Cold start yes
 Length of the battery string 36 – 44 psc. batteries 12V
Charging time 3 - 8 hours to 90% capacity (configurable)
Charging cycle According to DIN 41773 with automatic charging switch
According to the criterion of charging current and voltage with time control, the option of temperature compensation of the charging voltage
Dimensions and weight
UPS housing dimensions and weight (W x D x H) 600 x 980 x 1400 mm
259 kg
Signaling and communication ports
Work status indicator Touch LCD display, LED indicators, audible alarm
Communication RS232, RS485, MODBUS RTU / ASCII, Dry Contact, SNMP, REPO, parallel operation interface, interface with the genset
Environmental conditions
Noise level (depending on the number of power modules) <55 dB
Operating temperature 0 °C ÷ 40 °C
Recommended working temperature 15 °C ÷ 25 °C
Storage temperature -20°C ÷ 40°C
Humidity 0 ÷ 95% (without condensation)
Standards
Resistance to interference EN 62040-2 :2006 C3, EN 61000-2-2 :2002, EN 61000-4-2 :2009, EN 61000-4-3 :2006 +A1 :2008 +A2 :2010, EN 61000-4-4 :2004 +A1 :2010, EN 61000-4-5 :2006, EN 61000-4-6 :2009, EN 61000-4- 8 :2010, EN 61000-4-11 :2004
Safety CE, EN 62040-1 :2008, EN 60950-1:2006, IEC 60417
Optional equipment
- SNMP card,
- Charging voltage compensation system,
- Environmental conditions sensor (EMD)
- Batteries on a rack or battery modules
- Service Uninterruptible Bypass External

The publication lists the parameters of standard models. Due to continuous improvement of the product, we reserve the right to change parameters without prior information.
VI - Line Interactive (VI in accordance with PN-EN 62040-3)
VFI - True On Line (VFI in accordance with PN-EN 62040-3)

SELECT ANOTHER UPS

BW
Model
BW300
Type
VFI-SS-111
Range
30 - 300 kVA
Class
3:3
COMBO / Innova
Model
COMBO / Innova
Type
UPS VFI
Range
10 - 20 kVA
Class
3:1 / 1:1
CORE
Model
CORE
Type
UPS VFI
Range
1-10 kVA
Class
1:1
CORE 3K TL
Model
CORE 3K TL
Type
UPS VFI
Range
3 kVA
Class
1:1
HS105
Model
HS105
Type
UPS VFI
Range
50 - 100 kVA
Class
3:3
HS205
Model
HS205
Type
UPS VFI
Range
50 - 200 kVA
Class
3:3
HS305
Model
HS305
Type
UPS VFI
Range
50 - 300 kVA
Class
3:3
HS505
Model
HS505
Type
UPS VFI
Range
50 - 500 kVA
Class
3:3
UPS JR
Model
JR
Type
UPS VFI
Range
10 - 20 kVA
Class
3:3
MZ 20K-200K
Model
MZ 20K-200K
Type
UPS VFI
Range
20 - 200 kVA
Class
3:3
NGS
Model
NGS
Type
UPS VFI
Range
10 - 40 kVA
Class
3:3
PKX
Model
PKX
Type
UPS VFI
Range
10 kVA
Class
3:3
PRM 1K EC
Model
PRM 1K EC
Type
UPS VFI
Range
1 kVA
Class
1:1
UPS  WINTER
Model
WINTER
Type
UPS VI
Range
3 kVA
Class
1:1

SHORTCUTS

Do you need help?
Tel: +48 58 556 13 13
E-mail: info@comex.com.pl

comex Filing a Complaint
Tel: +48 58 556 13 13
E-mail: info@comex.com.pl