UPS UPS
NGS

SPECIFICATION
TECHNOLOGY:
True On-Line, Double Conversion
CLASSIFICATION CODE:
VFI - SS - 111
POWER RANGE:
10 - 40 kVA
PHASE CONFIGURATION:
3:3
SOFTWARE:
ClientMate

APPLICATIONS:

Computers network, Data processing centers, Industrial equipment, Clusters, Tele information systems, Automation and control systems

DOWNLOAD:

CHARACTERISTICS
  • Technology True On-Line Double Conversion Technology provides perfect output voltage parameters, regardless of the input voltage and the load.
  • Rectifier IGBT the most advanced technology which provides very low THDi and high power factor.
  • Automatic bypass provides continuous load supply in critical conditions, such as overheating or inverter failure.
  • Maintenance bypass enables service handling without necessity of shutting off the load.
  • Communication: RS232, RS485, MODBUS for UPS and load supervision and control,
  • DryContact alarm indicators; work with BMS system
  • SNMP integration with systems management network NMS.
  • Remote emergency power off (REPO) provides remote shutting off the load and UPS in the case of emergency.
  • Emergency power off (EPO) on UPS provides very quickly shutting off the load and UPS.
  • LCD control panel displays UPS and power parameters as well as hundreds of useful information.
  • Small dimensions requires small area for unit operation.
  • High efficiency (>96%) reduces heat dissipation and limits power consumption costs.
  • ECO-Mode gives possibility of significant cost reduction and in practice stops heat emission.
  • Automatic diagnostics and fully digital control (2x 32bit DSP) ensure that components and parameters are controlled without user interference.
  • High input power factor 0,99 reduces the value of current drawn from the mains.
  • The highest output power factor 1,0 allows load of versatile characteristics to be powered.
  • Wide input voltage range for normal mode ensures that batteries are used only if necessary – in fact, only when the input voltage is completely lost.
  • Wide input frequency range for normal mode gives possibility for seamless operation with different power sources – as mains or the generating set.
  • Simple maintenance microprocessor control and 24/7 operation mode means that unit does not require specialized handling.
  • Advanced battery management gives reliability of optimal charging and using batteries, elongates its lifetime and reduces operating costs.
  • Excellent voltage quality is provided by 3level IGBT inverter ad high frequency PWM technology, the output voltage has always stable parameters independent of input disturbances and the load characteristics.
  • Advanced software provides to customer full control of unit and load.
  • User configurable settings enable user to set nominal voltages, frequency, preferred operating modes.
  • Redundancy configurations:
    - parallel for capacity or redundancy
    - Hot Standby
PARAMETERS
Model NGS 10 NGS 15 NGS 20 NGS 30 NGS 40
Power 10 kVA / 10 kW 15 kVA / 15 kW 20 kVA / 20 kW 30 kVA / 27 kW 40 kVA / 40 kW
No. of phases: IN : OUT 3:3
Input
Nominal voltage 380 / 400 / 415 VAC
Voltage range (adjustable) -43% ÷ +20%
Frequency 50 / 60 Hz
Frequency range -20% ÷ +20%
THDi <3%
Input power factor ≥0,99
Output
Nominal voltage 380 / 400 / 415 VAC
Power factor 1,0 0,9 1,0
Static / dynamic voltage regulation ±1% / ±2%
Nominal frequency 50 / 60 ± 0,05 Hz
Overload capacity inverter 110% - 60 min., 125% - 10 min., 150% - 60 sec
Overload capacity bypass 125% - continuous, 130% - 10 min., 150% - 1 min
Shot-circuit resistance 340% value of nominal current for 200 ms
Efficiency in On-Line mode >96%
Efficiency in Eco Mode 99%
Crest factor 3:1
Batteries
Cold start Yes (option)
Amount of batteries in 1 string 36-44 psc. of batteries 12V
Charging time 3 – 8 hours up to 90% of capacity (configurable)
Charging cycle According to DIN 41773 with automatic disconnection of charging according to the criterion of current and voltage, with time control, option of temperature compensation of the charging voltage
Weight and dimensions
Dimensions and weight (W x D x H) 250 x 840 x 715 350 x 737 x 1335 500 x 840 x 1400
without internal batteries 51,5 kg 88,0 kg 140,0 kg
Communication
Working indicators LCD + indicators LED, sound alarm
Communication RS232, RS485
As option: MODBUS RTU/ASCII, USB, Dry Contact, SNMP, REPO, złącza pracy równoległej
Environmental
Noise level <58 dB @ load 100%, <52 dB @ load. 50%
Operating temperature for UPS 0 °C ÷ 40 °C
Recommended operating temperature for UPS 15 °C ÷ 25 °C
Storage temperature -20°C ÷ 40°C
Humidity 0 ÷ 95% (without condensing)
Certification
Standards EN 62040-2:2005, EN 62040-2:2006
Safety IEC62040-1-1, CE, 62040-3 :2001
Options
- Uninterruptible external maintenance bypass
- SNMP card
- Environmental sensor (EMD)
- Battery Cold Start
- Parallel card

Due to constant product improvement all specifications are subject to change without notice.
VI - Line Interactive (VI in accordance with PN-EN 62040-3)
VFI - True On Line (VFI in accordance with PN-EN 62040-3)

SELECT ANOTHER UPS

BW
Model
BW300
Type
VFI-SS-111
Range
30 - 300 kVA
Class
3:3
COMBO / Innova
Model
COMBO / Innova
Type
UPS VFI
Range
10 - 20 kVA
Class
3:1 / 1:1
CORE
Model
CORE
Type
UPS VFI
Range
1-10 kVA
Class
1:1
CORE 3K TL
Model
CORE 3K TL
Type
UPS VFI
Range
3 kVA
Class
1:1
HS105
Model
HS105
Type
UPS VFI
Range
50 - 100 kVA
Class
3:3
HS205
Model
HS205
Type
UPS VFI
Range
50 - 200 kVA
Class
3:3
HS305
Model
HS305
Type
UPS VFI
Range
50 - 300 kVA
Class
3:3
HS505
Model
HS505
Type
UPS VFI
Range
50 - 500 kVA
Class
3:3
UPS JR
Model
JR
Type
UPS VFI
Range
10 - 20 kVA
Class
3:3
MZ 20K-200K
Model
MZ 20K-200K
Type
UPS VFI
Range
20 - 200 kVA
Class
3:3
NHS 120
Model
NHS 120
Type
UPS VFI
Range
30 - 120 kVA
Class
3:3
PKX
Model
PKX
Type
UPS VFI
Range
10 kVA
Class
3:3
PRM 1K EC
Model
PRM 1K EC
Type
UPS VFI
Range
1 kVA
Class
1:1
UPS  WINTER
Model
WINTER
Type
UPS VI
Range
3 kVA
Class
1:1