UPS UPS
PRM 1K EC

SPECIFICATION
TECHNOLOGY:
True On-Line, Double Conversion
CLASSIFICATION CODE:
VFI - SS - 111
POWER RANGE:
1 kVA
PHASE CONFIGURATION:
1:1
SOFTWARE:
ViewPower

APPLICATIONS:

Servers, Workstations, lighting, lab equipment, security systems, automation and control systems

CHARACTERISTICS
  • True On-Line Double Conversion Technology (EN 62040-3) provides perfect output voltage parameters, regardless of the input voltage and the load.
  • Automatic Bypass (Static Switch) provides continuous load supply in critical conditions, such as overheating or inverter failure.
  • Frequency converter feature lets you set the output frequency to 50Hz or 60Hz.
  • USB, RS-232, Dry Contact for UPS (Uninterruptible Power Supply) and load supervision and control.
  • Ethernet Interface for computer-network communication with SNMP protocol support
  • Software controlled output sockets enable managing groups of load.
  • Small dimensions – power and battery modules have 2U, it makes installation and operation easy and compact.
  • High efficiency reduces heat dissipation and decreases operating costs.
  • ECO-Mode gives possibility of significant cost reduction and in practice stops heat emission. Efficiency up to 99%.
  • Backup time extension possibility provides exact fitting for required autonomy time.
  • Automatic diagnostics ensure that components and parameters are controlled without user interference.
  • High input power factor reduces the value of current drawn from the mains.
  • Wide input voltage range for normal mode ensures that the batteries are used only if necessary - in fact, only when the input voltage is completely lost.
  • Wide input frequency range for normal mode gives possibility for seamless operation with different power sources - as mains or the generating set.
  • Automatic start up ensures maintenance-free operation even after the unit was switched-off after long time mains failure.
  • Advanced Battery Management gives reliability of optimal charging and using batteries, elongates its lifetime and reduces operation costs.
  • Battery start up feature enables unit start up without mains supply.
  • Excellent voltage quality is provided by IGBT inverter and high-frequency PWM modulation method; the output voltage has always stable parameters, independent of input disturbances and load characteristics.
  • High overload capacity indicates power reliability during transient conditions and high resistance on handling faults.
  • Advanced power management software provides full control of UPS.
  • User configurable settings – nominal voltages, frequencies, preferred operating modes, ways of communication – widens the range of possible applications.
  • REPO – enables remote emergency power off, in case of emergency
  • High output power factor (PF=0.9) allows load of versatile characteristics to be connected.
  • Extra charger 6A allow to charging big capacity batteries when long backup time is needed.
PARAMETERS
Model PRM 1K EC
Rating 900W / 1000VA
Phases In : Out 1:1
Input
Mains voltage 208 / 220 / 230 / 240 Vac
Voltage range -30% ÷ +20% @ Load ≥70%
-48% ÷ +20% @ Load <70%
Frequency 50/60 Hz
Frequency range -20% ÷ +20%
Power factor ≥ 0,99
Output
Nominal voltage 208 / 220 / 230 / 240 Vac
Power factor 0,9
Voltage regulation static/dynamic ±1% / ±3%
Nominal frequency 50 / 60 ± 0,05 Hz
Overloads 112% - no limit, 125% - 3 min., 150% - 30 sec.
Efficiency On-Line (1) >92%
Efficiency Eco Mode 99%
Programmable output receptacles 2 x 4 pcs
Output receptacles IEC320-C13 x8
Crest factor 3:1
Batteries
Charger current 6A
Nominal battery voltage 36 Vdc
Battery "cold start" yes
External battery socket yes
Charging time 4 hours to 90% of capacity
Charging method According to DIN 41773. 3-stage charging level for extend battery life.
Weight and dimensions
Dimensions and weight of UPS (W x D x H) 192 mm x 460 mm x 347 mm
8,4 kg
Communications
User interfaces LCD panel + sound alarm
Communications RS232, USB, DryContact in/out, SNMP Slot, REPO
Environmental
Audible noise (6) <43 dB
Operating temperature 0°C ÷ 45°C
Recommended temperature 15 °C ÷ 25 °C
Storage temperature -25°C ÷ 55°C
Humidity 0 ÷ 95% (non-condensing)
Standards
EMC markings EN62040-2:2006, EN61000-3-2:2006, EN61000-3-3:2005, EN61000-4-2: 2005, EN61000-4-3: 2006, EN61000-4-4: 2006, EN61000-4-5: 2005, EN61000-4-6: 2006, EN61000-4-8: 2004, EN61000-4-11: 2004, EN61000-2-2: 2006
Safety markings CE, EN 62040-1:2008, IEC 60950-1
Options
- SNMP card
- Environmental sensor (EMD)
- External maintenance bypass
- REPO switch
- External battery modules (EBM)
- 19’’ Rail Kit
- AS-400 card (Relay Card)

Due to constant product improvement all specifications are subject to change without notice. (1)cosφ=0.9 and 100% of load; (2) cosφ=0.8;
VI - Line Interactive (VI in accordance with PN-EN 62040-3)
VFI - True On Line (VFI in accordance with PN-EN 62040-3)

SELECT ANOTHER UPS

BW
Model
BW300
Type
VFI-SS-111
Range
30 - 300 kVA
Class
3:3
COMBO / Innova
Model
COMBO / Innova
Type
UPS VFI
Range
10 - 20 kVA
Class
3:1 / 1:1
CORE
Model
CORE
Type
UPS VFI
Range
1-10 kVA
Class
1:1
CORE 3K TL
Model
CORE 3K TL
Type
UPS VFI
Range
3 kVA
Class
1:1
HS105
Model
HS105
Type
UPS VFI
Range
50 - 100 kVA
Class
3:3
HS205
Model
HS205
Type
UPS VFI
Range
50 - 200 kVA
Class
3:3
HS305
Model
HS305
Type
UPS VFI
Range
50 - 300 kVA
Class
3:3
HS505
Model
HS505
Type
UPS VFI
Range
50 - 500 kVA
Class
3:3
UPS JR
Model
JR
Type
UPS VFI
Range
10 - 20 kVA
Class
3:3
MZ 20K-200K
Model
MZ 20K-200K
Type
UPS VFI
Range
20 - 200 kVA
Class
3:3
NGS
Model
NGS
Type
UPS VFI
Range
10 - 40 kVA
Class
3:3
NHS 120
Model
NHS 120
Type
UPS VFI
Range
30 - 120 kVA
Class
3:3
PKX
Model
PKX
Type
UPS VFI
Range
10 kVA
Class
3:3
UPS  WINTER
Model
WINTER
Type
UPS VI
Range
3 kVA
Class
1:1

SHORTCUTS