UPS UPS
PS 10-40K

SPECIFICATION
TECHNOLOGY:
TRUE ON LINE Double Conversion
CLASSIFICATION CODE:
VFI-SS-111 (zg. z PN-EN 62040-3)
POWER RANGE:
10 ÷ 40 kVA
PHASE CONFIGURATION:
1:1, 3:1, 3:3, 1:3

 

APPLICATIONS:

Computer networks, Servers, Rack cabinets 19", Laboratory apparatus, Telecommunications, Automation and control systems

DOWNLOAD:

CHARACTERISTICS
  • True On-Line Double Conversion technology ensures excellent output voltage performance regardless of energy interference and the type of consumers being powered.
  • The universal design of the rectifier and inverter allows the UPS to be used in any input and output phase configuration of 1:1, 3:1 or 3:3, as well as 1:3
  • Separate feeding of the rectifier and Bypass tracks (Split Bypass) increases system reliability and enables operation in cascade systems.
  • IGBT rectifier the most advanced technology providing very low THDi and high power factor.
  • The automatic bypass - uninterruptible - ensures uninterrupted power supply to consumers in critical situations such as overheating or failure.
  • Communication interfaces:
    USB for monitoring and managing UPS operation.
    SNMP integration with NMS-type network management systems,
    Remote Emergency Power Off. (REPO) to provide remote disconnection of power supply to consumers in the event of fire,
  • The LCD control and monitoring panel and LED indicator allow the parameters and operating mode of the PSU to be diagnosed and events to be logged.
  • Small dimensions - modules suitable for installation in standard 19" racks.
  • The unit's high efficiency (>96%), achieved over a wide range of load values, limits the heat emitted, making eventual space cooling simpler and cheaper to operate.
  • ECO-Mode significantly reduces the operating costs of the unit and virtually eliminates heat emission.
  • Advanced software enabling the user to have full control over the unit and the powered loads.
  • The configurability of the operating parameters - nominal voltages, frequencies, preferred operating modes, method of communication - greatly expands the range of possible applications.
  • The high input power factor value of 0.99 limits the value of the current drawn by the unit from the mains.
  • The high output power factor of 1.0 allows the power supply to be loaded with full active power.
  • The wide input voltage range in normal operation ensures stable operation of the unit without the need for batteries, significantly extending battery life.
  • Automatic diagnostics and digital control guarantee full efficiency of the unit, control of components and operating parameters without user intervention.
  • The wide input frequency range in normal operation allows the power supply to be used freely in mains with unstable parameters and when powered by a generator set.
  • Simplicity of operation - the ease of connection to the mains and the simple switching on and off of the unit does not require any special skills on the part of the user.
  • Advanced battery management ensures optimal charging and utilisation of the battery bank, increases battery life and reduces operating costs.
  • Battery start ensures that the UPS can be switched on even if the mains supply is interrupted.
  • The excellent quality of the output voltage, achieved through the use of a 3-level IGBT inverter, using advanced PWM control technology means that a voltage with stable parameters is delivered, regardless of energy disturbances and the type of equipment being powered.
  • Redundant parallel operation - redundant parallel operation possible for increased power or reliability (N+1).
 UPS PS - 19'' rack installation with battery modules UPS PS - free-standing, Tower with battery modules

 

PS1.jpeg

 

PS2.jpeg

PARAMETERS
Model PS 10K PS 20K PS 30K PS 40K
Power 10 kVA / 10 kW 20 kVA / 20 kW 30 kVA / 30 kW 40 kVA / 40 kW
No. of phases IN : OUT 1:1, 3:1, 3:3, 1:3 3:3
Input
Nominal voltage [L-N] | [L-L] 220 / 230 / 240 VAC | 380 / 400 / 415 VAC
Voltage range
[L-N]
[L-L]

100 ÷ 160 VAC linearly for load. 50% - 100%, 160 ÷ 300 VAC for load 100%
174 ÷ 278 VAC linearly for load 50% - 100%, 278 ÷ 522 VAC for load 100%
Frequency 50 / 60 Hz
Frequency range 45 ÷ 65 Hz
THDi <3%
Input power factor ≥0,99
Output
Nominal voltage [L-N] | [L-L] 220 / 230 / 240 VAC | 380 / 400 / 415 VAC
Power factor 1,0
Static/dynamic voltage regulation ±1% / ±3%
Nominal frequency 50 / 60 ± 0,1 Hz
Overload resistance 105% bez limitu, 125% - 10 min., 150% - 30 s., >150% - 500 ms
Efficiency in On-line mode >96%
Efficiency in ECO mode 98%
Creast factor 3:1
Batteries
Number of batteries in 1 string 32 - 40 pcs. of batteries 12V
Charging current 1 - 13 A
Charging time 3 - 8 hours up to 90% capacity (configurable)
Charging cycle According to DIN 41773 with automatic charge deactivation according to current and voltage criteria, with time control, temperature compensation option for charging voltage
Dimensions and weight
Dimensions UPS W x D x H [mm] 440 x 680 x 132 (3U) 440 x 750 x 132 (3U)
Weight of 1 UPS module 25 kg 32 kg 36 kg 38 kg
Dimensions of 1 battery module W x D x H [mm] (20 bat.) 1 440 x 780 x 132 (3U)
Weight of 1 battery module (20 bats) 2 65 kg
Signalling and communication ports
Operating status indicator LCD, audible alarm
Communication USB, RS232, EPO, SNMP
Environmental conditions
Noise level (dependent on number of power modules) <65 dB @ load 100%
Permissible operating temperature 0°C ÷ 40°C
Recommended operating temperature 15°C ÷ 25°C
Storage temperature -20°C ÷ 40°C
Humidity 0 ÷ 95% (non-condensing)
Standards
Resistance to interference EN 62040-2:2018, EN 61000-3-2:2019, EN 61000-3-3:2013+A1:2019
Safety EN 62040-1:2019, EN 62040-1-2:2003, 62040-3:2001, CE
Optional equipment
- SNMP adapter
- Uninterruptible External Bypass, Service
- 19" rack-mounted or rack-mounted battery modules
- Remote Fire Protection Switch - REPO

1The UPS must have a minimum of 2 battery modules. Each of these modules is respectively the positive and negative half of the UPS battery chain, together they occupy 6U.
2Each UPS must have a minimum of 2 battery modules
.


Due to constant product improvement all specifications are subject to change without notice.
VI - Line Interactive (VI in accordance with PN-EN 62040-3)
VFI - True On Line (VFI in accordance with PN-EN 62040-3)

SELECT ANOTHER UPS

BASIC 1K
Model
BASIC 1K
Type
UPS VFI
Range
1 kVA
Class
1:1
CORE
Model
CORE 1K
Type
UPS VFI
Range
1 kVA
Class
1:1
CORE 3TL
Model
CORE 3TL
Type
UPS VFI
Range
3 kVA
Class
1:1
CORE
Model
CORE 6-10K
Type
UPS VFI
Range
6-10 kVA
Class
1:1
CORE ONE 2-3K
Model
CORE ONE 2-3K
Type
UPS VFI
Range
2-3 kVA
Class
1:1
FRAME
Model
FRAME 60-200K
Type
VFI-SS-111
Range
60-200 kVA
Class
3:3
HS305
Model
HS305
Type
UPS VFI
Range
50 - 300 kVA
Class
3:3
HS505
Model
HS505
Type
UPS VFI
Range
50 - 500 kVA
Class
3:3
JR 10-20K
Model
JR 10-20K
Type
UPS VFI
Range
10 - 20 kVA
Class
3:3 / 3:1
MR
Model
MR
Type
VFI-SS-111
Range
50 ÷ 600 kVA
Class
3:3
MY 30K
Model
MY 30K
Type
UPS VFI
Range
30 kVA
Class
3:3 / 3:1
MZ 60K-200K
Model
MZ 60K-200K
Type
UPS VFI
Range
60 - 200 kVA
Class
3:3
NGS 40K
Model
NGS 40K
Type
UPS VFI
Range
40 kVA
Class
3:3
PKX
Model
PKX 10K
Type
UPS VFI
Range
10 - 100 kVA
Class
3:3
WINTER 3K
Model
WINTER 3K
Type
UPS VI
Range
3 kVA
Class
1:1

SHORTCUTS

Pracownik w kasku ochronnym Do you need help?
Tel: +48 58 556 13 13
E-mail: info@comex.com.pl

comex Filing a Complaint
Tel: +48 58 556 13 13
E-mail: info@comex.com.pl