UPS UPS
BW

SPECIFICATION
BW
TECHNOLOGY:
True On-Line, Double Conversion
CLASSIFICATION:
VFI-SS-111 (EN 62040-3)
POWER RANGE:
30 - 300 kVA
No. OF PHASES:
3:3

APPLICATIONS:

Large computer networks, data processing centres, clusters, medical and industrial equipment, tele-information systems, automation and control systems

DOWNLOAD:

CHARACTERISTICS
  • True On-Line Double Conversion technology provides excellent output voltage parameters regardless of energy interference and the type of powered receivers.
  • Rectifier IGBT the most advanced technology ensuring very low THDi and
    high power factor.
  • Modular construction significantly simplifies and speeds up service activities (shortening the MTTR) and allows the UPS power to be adapted to the power loads in the range from 30 kVA to 300 kVA.
  • Automatic, uninterruptible STS ensures uninterrupted supply of receivers in critical situations such as overheating or failure.
  • Service bypass enables servicing of devices without switching off powered receivers. Separate power supply for the Bypass track gives the possibility to provide a backup power source for loads even in the event of a device failure or UPS protection in the main path.
  • Communication:
    RS232, USB to monitor and manage UPS work,
    DryContact relay contacts for cooperation with BMS systems,
    SNMP integration with NMS network management systems,
    Remote fire switch connector (REPO) to ensure remote disconnection of receivers power supply in the event of fire,
  • LCD 10 '' monitoring and monitoring panel (touchscreen) gives the possibility to diagnose the parameters and the operating mode of the power supply, enables the recording of events and configuration of the UPS.
  • Small dimensions The 300 kVA UPS occupies a space of 0.66 m² and provides power packing at 455 kW / m².
  • High device efficiency (> 96%) over a wide load range limits the heat emitted, making room cooling easier and operating costs low.
  • ECO-Mode allows a significant reduction in the operating costs of the device and virtually eliminates heat emissions.
  • Dual Input Lines that is, the possibility of using separate rectifier and Bypass power supply paths increases the availability of power supplies to the receivers.
  • Automatic diagnostics and digital control (32 bit DSP x2) guarantees full device efficiency, control of components and operating parameters without the need for user intervention.
  • High value of input power factor 0.99 limits the current drawn by the device from the network.
  • High output power factor of 1.0 allows the UPS to be charged with the maximum active power.
  • Wide input voltage range in normal operation mode, it ensures stable operation of the device without the need for batteries, which significantly increases their lifetime.
  • Wide input frequency range in normal operation mode, it allows free use of the power supply in a network with unstable parameters and when powered from a power generator.
  • Simple of use easy connection to the network and simple switching the device on and off does not require any special qualifications from the user.
  • Advanced battery management guarantees optimal charging and use of accumulator batteries, increases their service life and reduces operating costs. Charging voltage temperature compensation function.
  • Very efficient charging systems each power module has a built-in separate battery charging system, thanks to which it is possible to use high-capacity batteries for long battery life.
  • Excellent output voltage quality achieved thanks to the use of a 3-level IGBT inverter, using advanced PWM control technology, ensures that voltage with stable parameters is supplied, regardless of energy interference and the type of powered devices.
  • High overload ensures device protection and power continuity in the presence of transient transients.
  • Advanced software enabling the user full control over the device and powered receivers.
  • Configurability of operating parameters nominal voltages, frequencies, preferred modes of operation, communication method - significantly expands the range of possible applications.
  • Redundant configurations:
    - redundancy of N + 1 or N + X power modules
    - parallel redundancy operation to increase 1 + 1 reliability
    - parallel capacitive operation for increasing power x2
    - HotStandby work
PARAMETERS
Model BW300
Capacity kVA 30 - 300 kW/kVA
Number of phases IN:OUT 3:3
Capacity of power module 30 kW/kVA
Hotswap power module Yes
Possibility of configuration 10, 15, 20, 25 or 30 kW power module
Input
Voltage 380 / 400 / 415 VAC
Voltage range 305 – 478 Vac for load ≥70%
208 – 478 Vac for load <70%
Frequency 50 / 60 Hz
Frequency range -20% ÷ +20 %
THDi <3%
Input power factor ≥ 0,99
Output
Voltage 380 / 400 / 415 VAC
Voltage regulation static/dynamic ±1% / ±2%
Frequency 50 / 60 ± 0,05 Hz
Overload capacity 110% - 60 min., 125% - 10 min., 150% - 60 s, >150% - 200 ms
Efficiency >96%
Eco Mode efficiency 99%
Crest factor 3:1
Batteries
Type Maintenance free, sealed VRLA AGM
Quantity 32/36/40 pcs
Cold start yes
Charging 4 – 8 hours up to 90% of capacity, in accordance with DIN 41773
Weight and dimensions
Weight and dimensions of cabinet
(WxDxH)
BW STS
600 mm x 1100 mm x 2000 mm
275 kg
Weight and dimensions of power
module (WxDxH)
BW PM 30
440 mm x 650 mm x 135 mm (3U)
34,5 kg
Communications
Operation mode indicators LCD touch screen, LED indicators, sound alarm
Communication RS-232, USB, Dry Contact, SNMP slot, REPO, parallel work connector, Automatic diagnostic and error logs. Logs error > 2600 
Environmental
Noise Level depending the load
and temp.
< 60 dB (A)
Operating temperature for UPS 0 °C ÷ 40 °C
Recom. operating temperature for
UPS and batteries
15 °C ÷ 25 °C
Storage temperature -20°C ÷ 40°C
Humidity 0 ÷ 95 % (without condensation)
Standards
Standards CE, EN62040-1:2008, EN62040-2:2006,
Options
- SNMP Web
- Environmental sensor (EMD)
- REPO
- External battery cabinets
- External Maintenance Bypass
- 30kVA Power modules

VI - Line Interactive (VI in accordance with PN-EN 62040-3)
VFI - True On Line (VFI in accordance with PN-EN 62040-3)

SELECT ANOTHER UPS

BASIC 1K
Model
BASIC 1K
Type
UPS VFI
Range
1 kVA
Class
1:1
BM
Model
BM
Type
VFI-SS-111
Range
300-1200 kW
Class
3:3
CORE
Model
CORE 1-3
Type
UPS VFI
Range
1-3 kVA
Class
1:1
CORE 3K TL
Model
CORE 3K TL
Type
UPS VFI
Range
3 kVA
Class
1:1
CORE
Model
CORE 6-10
Type
UPS VFI
Range
6-10 kVA
Class
1:1
HS105
Model
HS105
Type
UPS VFI
Range
50 - 100 kVA
Class
3:3
HS205
Model
HS205
Type
UPS VFI
Range
50 - 200 kVA
Class
3:3
HS305
Model
HS305
Type
UPS VFI
Range
50 - 300 kVA
Class
3:3
HS505
Model
HS505
Type
UPS VFI
Range
50 - 500 kVA
Class
3:3
UPS JR
Model
JR
Type
UPS VFI
Range
10 - 20 kVA
Class
3:3 / 3:1
MR
Model
MR
Type
VFI-SS-111
Range
50 ÷ 600 kVA
Class
3:3
MY 30K
Model
MY 30K
Type
UPS VFI
Range
30 kVA
Class
3:3 / 3:1
MZ 60K-200K
Model
MZ 60K-200K
Type
UPS VFI
Range
60 - 200 kVA
Class
3:3
NGS 40
Model
NGS 40
Type
UPS VFI
Range
40 kVA
Class
3:3
NHS 120
Model
NHS 120
Type
UPS VFI
Range
30 - 120 kVA
Class
3:3
PKX
Model
PKX
Type
UPS VFI
Range
10 kVA
Class
3:3
PRM 6
Model
PRM 6
Type
UPS VFI
Range
6 kVA
Class
1:1
UPS  WINTER
Model
WINTER
Type
UPS VI
Range
3 kVA
Class
1:1

SHORTCUTS

Do you need help?
Tel: +48 58 556 13 13
E-mail: info@comex.com.pl

comex Filing a Complaint
Tel: +48 58 556 13 13
E-mail: info@comex.com.pl