UPS PERIPHERALS
ATS 16M / 16S

SPECIFICATION
CLASS:
Automatic Transfer Switch ATS
POWER RANGE:
16A
PHASE CONFIGURATION:
1:1

APPLICATIONS:

Auto Transfer Switch (ATS), Automatic Bypass allows provide supply from 2 independent sources for sensitive equipment like: servers, workstations, routers, control systems and automation, laboratory equipment, security systems, cabinets Rack 19'

DOWNLOAD:

CHARACTERISTICS
  • Automatic transfer switch provides instant power to the receivers between two sources in critical situations such as power failure in one of the paths, or the emergence of unstable power supplies.
  • ATS 16M guarantees cooperation with any source of power, eg professional network, UPS, aggregate.
  • ATS 16S in addition to the advantages of the ATS 16M version has the option of remote manage (On/Off) of each output independently.
  • Efficiency 16A provides a wide range of receivers with a total power consumption of 3.6 kVA.
  • Automatic AC detection allows for full real-time control of power supply parameters at the ATS-16 inputs to ensure that the power supply is switched as quickly as possible.
  • Automatic return to the selected main power maintains the selected power path whenever a selected source is available and meets the required voltage specifications.
  • Automatic current detection the output is protected against overload.
  • LCD display and LED panel provides clear information about the status of the power source, the current power supply path, and the load parameters.
  • Real-time measurement voltage, frequency, current, active power and kWh power consumption allow you to control the power and power consumption both locally from the LCD panel and remotely via SNMP.
  • Select your preferred power source ensures that the voltage supplied to the receivers will come from a user-selected source, eg UPS.
  • Adjustable voltage and frequency tolerances provides stable power conditions for critical receivers.
  • Communication SNMP provides remote monitoring of device operation, configuration and parameter reading.
  • Event notifications with the possibility to send directly to the user via email and SNMP traps
  • Overload and overheat protection ensures full protection of the device from the effects of transient and erroneous operation.
  • Distribution panel of voltages equipped with 10 slots, you can connect multiple receivers. There are 8 IEC320-C13 sockets with a rated current rating of 10A and two 16A IEC320-C19 sockets.
  • Small size (1U) and the ability to mount in a rack 19 "rack space provides minimal space for installation.
  • Upgrade firmware user can access the latest development solutions.
  • Ease of management from any web browser.
  • Data log Real-time analyzes of historical events such as power outages, parameter instability,
  • Co-operation with environmental sensor provides the ability to monitor environmental parameters such as temperature, humidity or other events such as flood,
  • Soft start allows the delayed outputs to be switched on sequentially.
PARAMETERS
Model ATS 16M ATS 16S
Number of phases 1:1
Input
Voltage 200 - 240 Vac
Current 16 A
Frequency 50 / 60 Hz
Number of input sockets 2 x IEC320-C20 (2x 16A)
Output
Voltage Identical to the input
Frequency Identical to the input
Current 16 A
Switching time < 10 ms
Output sockets IEC320-C13 x 8 pcs(10A)
IEC320-C19 x 2 pcs (16A)
Dimensions and weight
Dimensions ATS (W x H x D) 434 x 44 (1U) x 250 mm
Weight 3,8 kg
Communication
Control panel LED panel, LCD display
Communication RS-232, SNMP - option (TCP/IP, UDP, DHCP, SNMP, HTTP)
Controlling output sockets n/a The ability to control on / off each socket independently
Environmental conditions
Operating temperature 0 °C ÷ 45 °C
Storage temperature -25 °C ÷ 75 °C
Humidity 0 ÷ 95% (without condensation)

The standard models are given in the publication. Due to continuous improvement of the product, the possibility of changing parameters without prior notice is reserved.
VI - Line Interactive (VI in accordance with PN-EN 62040-3)
VFI - True On Line (VFI in accordance with PN-EN 62040-3)

SELECT ANOTHER UPS

BW
Model
BW300
Type
VFI-SS-111
Range
30 - 300 kVA
Class
3:3
COMBO / Innova
Model
COMBO / Innova
Type
UPS VFI
Range
10 - 20 kVA
Class
3:1 / 1:1
CORE
Model
CORE
Type
UPS VFI
Range
1-10 kVA
Class
1:1
CORE 3K TL
Model
CORE 3K TL
Type
UPS VFI
Range
3 kVA
Class
1:1
HS105
Model
HS105
Type
UPS VFI
Range
50 - 100 kVA
Class
3:3
HS205
Model
HS205
Type
UPS VFI
Range
50 - 200 kVA
Class
3:3
HS305
Model
HS305
Type
UPS VFI
Range
50 - 300 kVA
Class
3:3
HS505
Model
HS505
Type
UPS VFI
Range
50 - 500 kVA
Class
3:3
UPS JR
Model
JR
Type
UPS VFI
Range
10 - 20 kVA
Class
3:3
MZ 20K-200K
Model
MZ 20K-200K
Type
UPS VFI
Range
20 - 200 kVA
Class
3:3
NGS
Model
NGS
Type
UPS VFI
Range
10 - 40 kVA
Class
3:3
NHS 120
Model
NHS 120
Type
UPS VFI
Range
30 - 120 kVA
Class
3:3
PKX
Model
PKX
Type
UPS VFI
Range
10 kVA
Class
3:3
PRM 1K EC
Model
PRM 1K EC
Type
UPS VFI
Range
1 kVA
Class
1:1
UPS  WINTER
Model
WINTER
Type
UPS VI
Range
3 kVA
Class
1:1

SHORTCUTS

Do you need help?
Tel: +48 58 556 13 13
E-mail: info@comex.com.pl

comex Filing a Complaint
Tel: +48 58 556 13 13
E-mail: info@comex.com.pl